
Zebra Printers
Option
Field
Clock
Indicator
s
Specify the character(s) that will precede and indicate a time/date value.For example, the
default indicator for the primary clock is %. There are no default indicators for the
secondary and tertiary clocks. Most printable characters are acceptable except those that
conflict with ZPL II commands.Refer to your ZPL II manual (volume 2) for more
information.
If indicators for secondary and tertiary clocks are entered, separate the characters with a
comma.
Set
Date/Ti
me
This displays options for the current clock date/time. Select AM, PM, or Military time format.
Set Clock
Offset
This displays options for the secondary and tertiary clocks.Time and date are determined by
adding the offsets to the primary clock reading.The Language selection determines the
language to use for the days and the months.
In Start Time mode, the time printed on the label is the Real Time Clock time when label
formatting begins. In Time Now mode, the time printed on the label is the Real Time Clock
time when label is placed in the print queue.
Real Time Clock can be set either in the printer's LCD or from the printer's PSO dialog. Fields that will be
using Real Time Clock should be defined as “fixed fields” in Loftware.The fields must use the reserved
field name of
ZtimeFieldxxx
, where x allows for unique identification. Only the first 10 characters of
the reserved field name are evaluated, and so the field can be uniquely defined after the reserved portion.
The fixed fields must provide the date formatting as data.
As a minimum, the Field Clock Indicator should contain a % for use with the primary clock.If all three
clocks are used the suggested syntax for the Field Clock Indicators might look like: %,#,@
Note: The symbols ^ and ~ are excluded from use. Any symbol not expected to be used in the printed output
may be used.
Sample data in the fixed field may be as follows based on the above field indicator settings:
Field Name (in Properties dialog) – ZtimeFieldCurDate
Primary clock data: %A, %B %d, %Y %I:%M
Printed result: Monday, January 01, 2001 01:06
Field Name (in Properties dialog) – ZtimeFieldSecDate
Secondary clock data: #A, #B #d, #Y #I:#M
Secondary clock offset values all set to 3
Printed result: Sunday, April 4, 2004 04:07
Field Name (in Properties dialog) – ZTimeFieldTerDate
Tertiary clock data: @A, @B @d, @Y @I:@M
Tertiary clock offset values all set to 5
Printed result: Tuesday, June 06, 2006 06:12
Zebra RFID Printer Options
The following information applies to Loftware-supported Zebra RFID printers.
Loftware LabelManager Version 10.1.1 User's Guide
497
Kommentare zu diesen Handbüchern