Data Sources for RFID Fields
Setting Description
New
Field
When selected, a field name can be entered in the Data column that does not yet exist on
the label but will be specified later.
EPC
Available for the EPC block; when selected, you can launch the EPC Configuration dialog
from the Data column. Refer to the EPC Encoding Types section for information. Once
the EPC portion has been configured, the Data column for this row will show the EPC
Encoding Type.
DoD When selected, you can launch the DOD Configuration dialog from the Data column.
URI
When selected, you can launch the URI Configuration dialog from the Data column.
Note: There can be only one block with an EPC, DoD, or URI data source for a
label. Once you have a block configured using URI of any of the EPC or DoD
encoding types, other blocks that you wish to configure must use any of the other
data sources (Unused, Fixed, New Field, or Field).
Input
Type
The format of the data input. Selections include ASCII, Decimal, and Hexadecimal.
Depending on the requirements of the device and the selected option, conversions may
be applied to the data being passed to the device.
Padding
When data for a block is smaller than the data allocated for the block, the Bytes value is
shown in red. You must select whether the padding should be added to the Left or to the
Right of the data. None, for no padding, is the default.
Pad Char
When Left or Right padding is selected for a block that requires data padding, the
character that will be used for padding can be selected Zero or Space.
Bytes
This is the size in bytes of the data for this block. This is filled in once the block has been
configured and depends on the selected Data Source and the Data being sent to the
device. If this is shown in red, the data value is either too small or too big for the block.
Block
Size
The maximum size (in bytes) of the block. If data defined for the block is too small or too
large for the block, a warning message is displayed. See Padding and Overflow settings.
Lock and Lock Tag After Writing
l UHF 64-bit / UHF 96-bit Class 1 Gen 1- For these tags, you must first specify a PC to lock the EPC
block or to enable the Lock Tag After Writing setting. The Lock check box of the PC block is
disabled.
l UHF 96-bit Class 0+ - EPC / USR blocks can be locked and Lock Tag After Writing can be enabled,
passcode is not required (no passcode field).
For the above tags (UHF 64-bit, UHF 96-bit Class 1 Gen 1, UHF 96-bit Class 0+), the Lock box is an L (on)
or OFF setting. When Lock Tag After Writing is enabled for these tags, the Lock state of the EPC or the
USR block cannot be changed without first turning Lock Tag After Writing off.
l UHF ISO 18000-6B, UHF UCODE EPC 1.19 Each has only one block and its Lock box is
disabled. However, Lock Tag After Writing can be set.
l HF - Lock can be set for each block. Lock Tag After Writing can be set.
l UHF Class 1 Gen 2 - To set the Lock setting to anything other than Off for the KP or the EPC
block, the Access Password (AP) must be set. The available Lock options depend on the target
device: