Printing RFID Smart Labels
Example 11 – Encoding Data
Scenario 2 (Encode)
You have designed an RFID Smart Label as described in the preceding sections. After printing the label
with your data, you want to make sure that the EPC / DOD code in the tag obtained the correct value.
Use the bottom section of the utility to enter the encoding type and your data.
The purpose of this example is to verify the values using the Loftware RFID Calculator. In this example,
SGTIN-96 ALT encoding was used with the following values:
SGTIN-96 ALT encoding sample data
Encoding Type SGTIN-96 ALT
Filter Value 3
Company Prefix 614141
Item Reference 527
Serial Number 3201
Indicator Digit 0
1. Select Options | RFID Calculator.
2. Click Select Encoding Type, and select SGTIN-96 ALT from its drop-down list.
3. Type in the values from the table above.
4. Click Encode.
The Encoded Result in hex format is shown:
307A57BF400083C000000C81
.
To obtain the URI value, cut and paste the Encoded Result value into the HEX Value box of the Decode
section, and then clickDecode.Conversely, to encode a URI value, click Enter URI, type in the URI, and
then click Encode.
Printing RFID Smart Labels
Printing an encoded smart label is very similar to printing a regular barcode label.Once you have
created your RFID Smart Label and configured the target RFID printer, the smart label can be printed
using any Loftware application or development tool.Two of the development tools have the capability of
passing the calculated EPC/DOD data back to the front end application.
Related Information
Refer to the
Loftware Print Server User's Guide
for more information.
Loftware LabelManager Version 10.1.1 User's Guide