AMT Datasouth Fastmark M1 Betriebsanweisung Seite 190

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 532
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 189
Using RFID with Loftware Label Manager
9. For the SSCC field, set the data Source to Field.For its Data value, select the GS1-128 (UCC-128)
barcode field.
10. Click OK from each of the dialogs to return to the design area.
l This sample is valid for 96 bit RFID Smart Labels containing a GS1-128 (UCC-128) SSCC barcode
field.
l The Extension Digit, Company Prefix, and Serial number are automatically derived from the data
in the barcode field.
l You may use the SSCC-96 ALT encoding if you do not have an SSCC barcode from which to
derive the data.The ALT encoding allows you to send your data as Company Prefix, Serial
Reference, and Extension Digit. This can be set up in your label similar to Example 6.
Related Information
For all examples given in this section, you can use the Loftware RFID Calculator to help you verify the encoded
data.Encoding and decoding examples of using this tool are provided in this guide.
Refer to the Serial Shipping Container Code (SSCC) section for a description of the fields on this dialog.
Example 6 - 64 bit SSCC Label
If you are using 64 bit labels, the RFID code cannot be derived from the existing barcode because the
specification calls for a Company Prefix Index as opposed to the actual Company Prefix. This index is
supplied to each manufacturer via the GS1 and EPCglobal US organizations as a temporary measure
until they can comply with the 96 bit mandates.
This means that you will still have to supply the data to the barcode as you normally would and use
non printing fields and formulas to derive the Serial Reference and the Company Prefix Index
fields.This example is similar to Example 3 in the SGTIN section.This is a bit more complicated to set
up than Example 5, but you still do not have to supply any extra data at print time.
SSCC-64 - Concatenates the following bit fields from most significant to least significant: Header, Filter
Value, Company Prefix Index, and Serial Reference.
Note: This example cannot be used for Class 1 Generation 2 (C1G2) tag types.Generation 2 tags require a 96-
bit EPC identifier.
1. Load or create the RFID Smart Label. This is a label that has a GS1-128 (UCC-128) SSCC barcode
field from which the SSCC value will be derived.In addition, it has a Serial Number field which,
for this example, has the following properties:
a. Printing Field is set to No.
b. Data Source is set to Formula using the Mid-String operation with the SSCC Barcode field, 11,
and 9 values.The formula will be similar to "mid(Barc0001,11,9)." This will automatically grab
9 digits from the barcode starting at position. If your serial number is embedded differently,
adjust the formula accordingly.
2. Double-click the RFID antenna icon.Alternatively, select and then right click the RFID antenna
icon. From the popup menu, select Edit Data Source.
Loftware Label Manager Version 10.1.1 User's Guide
190
Seitenansicht 189
1 2 ... 185 186 187 188 189 190 191 192 193 194 195 ... 531 532

Kommentare zu diesen Handbüchern

Keine Kommentare